Câu trả lời rất đơn giản
Khi các bạn sử dụng Cisco switch. Chúng ta sử dụng 2 câu lệnh ẩn của Cisco như sau
service unsupported-transceiver no errdisable detect cause gbic-invalid
Sau khi cắm module vào các bạn sẽ thấy trên switch hiện ra vài dòng log
VTN-HN-DA-SW1(config)#service unsupported-transceiver Warning: When Cisco determines that a fault or defect can be traced to the use of third-party transceivers installed by a customer or reseller, then, at Cisco's discretion, Cisco may withhold support under warranty or a Cisco support program. In the course of providing support for a Cisco networking product Cisco may require that the end user install Cisco transceivers if Cisco determines that removing third-party parts will assist Cisco in diagnosing the cause of a support issue. Jul 5 13:29:19.287: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/50 has bad crc Jul 5 13:29:19.290: %PHY-4-UNSUPPORTED_TRANSCEIVER: Unsupported transceiver found in Gi1/0/50
và check inventory sẽ thấy 1 module xuất hiện:
SW65-reserved#sh inv
NAME: "1", DESCR: "WS-C2960X-48TD-L"
PID: WS-C2960X-48TD-L , VID: V02 , SN: FOC1849S04T
NAME: "GigabitEthernet1/0/50", DESCR: "unsupported"
PID: , VID: , SN: F16CJU00470
SW65-reserved#sh int transceiver
If device is externally calibrated, only calibrated values are printed.
++ : high alarm, + : high warning, - : low warning, -- : low alarm.
NA or N/A: not applicable, Tx: transmit, Rx: receive.
mA: milliamperes, dBm: decibels (milliwatts).
Optical Optical
Temperature Voltage Tx Power Rx Power
Port (Celsius) (Volts) (dBm) (dBm)
--------- ----------- ------- -------- --------
Gi1/0/50 36.8 3.21 -5.9 -3.9
Tất cả mọi thứ đã OK, giờ các bạn chỉ việc sử dụng nó như bình thường thôi, rẻ hơn là mua hàng chính hãng 😀